Choose PC Based Holter Analysis
Trillium Silver Holter Analysis Software provides easy-to-use Windows® PC based editing and analysis of Holter monitoring data from our Trillium 2000™, Trillium 3000™, and Trillium 5000™ Holter Recorders. Trillium Silver based Holter Monitoring Systems allow you to get started with just a single recorder for 2 or 3 channel, 24 hour, monitoring applications. They are easily and economically expandable to multiple recorders and workstations.
Qualify for Maximum Reimbursement
The diagnostic procedures that can be performed with Trillium Silver based Holter Monitoring Systems qualify for maximum reimbursement (CPT Code 93230).
Enhance Patient Retention
The diagnostic quality report produced by our Trillium Silver Holter Analysis Software can be used to determine if a referral to another provider is actually required. By reducing the number of unnecessary referrals you can enhance patient retention rates and improve patient satisfaction with your service while simultaneously helping to reduce the overall cost of health care.
Discover the Value Leader in Holter
Forest Medical Holter Monitoring Systems are surprisingly affordable and provide the best long term value in Holter monitoring technology. Trillium Silver based systems can be upgraded to our Trillium Gold™ or Trillium Platinum™ Holter Analysis Software when you’re ready for more advanced analysis techniques. By choosing Forest Medical, you can be sure that you’ve made the right investment in Holter monitoring technology now and for the future.
Capabilities
Overview
• Windows 32 Bit (Win 98 SE and beyond)
• Point and click, web browser-like operation
• Each report page is displayed on screen
• Color-coded arrhythmias
• No limit to number of patient files that can be
stored on disk
• On-screen help, tutorial, and hints
Editing
• Enter Cover Page data
• Delete or add Report Strips
• Delete or add individual episodes, or delete
all episodes
• Designate Artifact from Full Disclosure
• Report data is automatically recalculated
• Parameter Settings
• Change Report Strip Label
On-Screen Calipers
• Measure time intervals or ST level
• Caliper Interval Repeat
• Calipers can be saved with strip
Report
• Memory Card Data (MCD) File Storage
• One Page Report Option
Cover Page
• Patient Information
• Medications / Symptoms
• Physician Information
• Conclusions
• Parameter Settings
• Initial Signal Quality
• ICD-9 CM Drop Down Box
Narrative Summary
• Initial Signal Quality
• Total QRS Complexes
• Average, Maximum, and Minimum Heart Rate
• Total Ventricular Ectopic Beats (VE)
• Isolated Ventricular Ectopic Beats
• Bigeminy, duration
• Trigeminy episodes
• Couplets (VE Pairs)
• Ventricular Runs, duration, longest and fastest
• Total Supraventricular Ectopic Beats (SVE)
• Isolated Supraventricular Ectopic Beats
• SVE Pairs
• SV Bigeminy
• SV Trigeminy
• Supraventricular Tachycardia (SVT), duration,
longest and fastest
• Irregular Rhythm, duration
• Tachycardia, duration
• Bradycardia, duration
• Pauses (Asystole)
• Longest Pause (Asystole)
• ST Depression / Elevation
• Patient Events
Hourly Summary
• Average, Maximum, and Minimum Heart Rate
• Isolated Ventricular Ectopic Beats
• Bigeminy
• Couplets (VE pairs)
• Ventricular Runs
• Isolated Supraventricular Ectopic Beats
• SV Couplets
• Supraventricular Tachycardia (SVT)
• Tachycardia
• Bradycardia
• Pauses (Asystole)
• ST Depression / Elevation
• Patient Events
Graphs
• Heart Rate
• Ventricular Ectopics
• Ventricular Runs
• Supraventricular Ectopics
• Supraventricular Tachycardia
• Artifact Index (2 or 3 channel)
• ST Level (2 or 3 channel)
• Normal R-R Histogram
• Abnormal R-R Histogram
Ventricular Forms
• Beat count and sample of up to eight
Ventricular Forms
Strips
• Automatic Report Strips in full-scale (25 mm/sec) or mini-scale (8.5 mm/sec) format
• Automatic Report Strips 8, 18, or 32 per page
• Strip List
• Extract strip from any time in the monitoring
period
• Extract all strips for an episode type
Full Disclosure
• Print in 1 Hour Increments
• 15, 30, or 60 seconds per line
• 1 Channel Only
• Any combination of 2 or 3 channels
• Patient event indicated by circle
Electronic Medical Records Support
Supported Recorders
• Trillium 2000™ Holter Recorder
• Trillium 5000™ Holter Recorder
• Trillium 3000™ Holter Recorder/Analyzer
Available Downloads
• Trillium Silver™ Holter Analysis
Software Data Sheet (PDF: 257 KB)
• Trillium 2000™ Holter Recorder
Data Sheet (PDF: 90 KB)
• Trillium 5000™ Holter Recorder
Data Sheet (PDF: 98 KB)
• Trillium 3000™ Holter Recorder/Analyzer
Data Sheet (104 KB)
• Summary Report
(PDF: 109 KB)
• Strips 2 Per Page
(PDF: 2.74 MB)
• Strips 18 Per Page
(PDF: 240 KB)
• Full Disclosure 15 Seconds
(PDF: 3.48 MB)
• Full Disclosure 30 Seconds
(PDF: 1.51 MB)
• Full Disclosure 60 Seconds
(PDF: 719 KB)
Minimum Computer Requirements
Windows 98SE; 2000; or XP, 150 MHz PII or above,
32 MB of Memory, 100 MB of Hard Disk space,
SVGA Video, (2) available USB Ports, and
a 300 dpi or higher resolution printer
|